Get a Quote Phone : +91-7838002712 / TEL : 011-45013465

DC Power Supply

DC Power Supply

DC-Regulated-Power-Supply-501

DC Power Supply at Crown Electronics Systems

A power supply must deliver consistent and exact voltage and current with little noise to any type of load: resistive, inductive, low impedance, high impedance, steady-state, or variable. The power supply is the most important component of any industry. DC power supply provides a controlled DC output to power a component, module, or device.
Crown Electronics Systems manufactures on a wide scale dependable, most precise, completely specified, certified, and efficient power supply equipment with powerful output protection and fault detection capabilities. We are one of the prominent DC Power Supply Manufacturers in India and our DC Power Supplies are manufactured for a variety of applications with varying Voltage and Current parameters.

Our Models

DC REGULATED POWER SUPPLY 0 - 32V

CES-502-image

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 1A CES - 504

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
CES-502-image

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 2A CES - 503

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
CES-502-image

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 5A CES - 502

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUTVOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUTCURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC-Regulated-Power-Supply-501

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 10A CES - 501

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC-Regulated-Power-Supply500

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 20A CES - 500

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
CES---513_509-3_505

DC REGULATED POWER SUPPLY
0 - 32V / 0 - 30A CES - 505

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
COOLING : Force Air Cooling
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

Our Models

DC REGULATED POWER SUPPLY 0 - 64V

CES-502-image

DC REGULATED POWER SUPPLY
0 - 64V /0-1A CES - 506

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
CES-502-image

DC REGULATED POWER SUPPLY
0 - 64V /0 - 2A CES - 507

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC-Regulated-Power-Supply-501

DC REGULATED POWER SUPPLY
0 - 64V /0 - 5A CES - 508

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC-Regulated-Power-Supply500

DC REGULATED POWER SUPPLY
0 - 64V /0 - 10A CES - 509

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC-Regulated-Power-Supply500

DC REGULATED POWER SUPPLY
0 - 64V /0 - 20A CES - 509-2

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
CES---513_509-3_505

DC REGULATED POWER SUPPLY
0 - 64V /0 - 30A CES - 509-3

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 1 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

Our Models

DC REGULATED POWER SUPPLY 0 - 128V

CES-502-image

DC REGULATED POWER SUPPLY
0 - 128V /0 - 1A CES - 510

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC-Regulated-Power-Supply-501

DC REGULATED POWER SUPPLY
0 - 128V /0 - 2A CES - 511

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC-Regulated-Power-Supply500

DC REGULATED POWER SUPPLY
0 - 128V / 5A CES - 512

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
CES---513_509-3_505

DC REGULATED POWER SUPPLY
0 - 128V / 0 - 10A CES - 513

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 2 mV
COOLING : Force Air Cooling
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

Our Models

DC REGULATED POWER SUPPLY 0 - 300V

CES---513_509-3_505

DC REGULATED POWER SUPPLY
0 - 300V / 0 - 5A CES - 715

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC-Regulated-Power-Supply500

DC REGULATED POWER SUPPLY
0 - 300V / 0 - 2A CES - 716

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load
DC-Regulated-Power-Supply-501

HIGH VOLTAGE DC REGULATED POWER SUPPLY
0 - 300V/0 - 1A CES - 717

INPUT VOLTAGE : 230V ± 10% AC 50 Hz
OUTPUT VOLTAGE : Continuously Variable with Coarse & Fine Control
OUTPUT CURRENT : Settable with Coarse & Fine Control
LOAD REGULATION CV : ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION CC : + 0.05% + 1mA From no load to full load
LINE REGULATION CV : ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION CC : + 0.01% + 1mA for +10% variation input voltage
RIPPLE : 3 mV
METER : Two Digital meters to monitor the output voltage & current
PROTECTION : Against short circuit & over load

Know More

Top Dc Power Supply With Excellent Performance And Dependability

Crown Electronics Systems provides a wide range of DC power supply, as well as a variety of voltage and current ranges, from tiny to large capacitance. Because all models like Dual Output Regulated Dc Power Supply, support arbitrary and variable voltage and current settings, they are appropriate for a wide range of applications ranging from simple stabilization to integration, testing, and evaluation.
DC-Regulated-Power-Supply
We are the most trusted DC Power Supply Suppliers in India, providing power supply with a smooth and steady output voltage at 100% conversion efficiency, independent of changes in the voltage, load current, or ambient temperature,

Our Models

Various Applications & Features Of
DC Power Supply

Need assistance?

If you have any queries related to our products or want assistance with any of our products, kindly let us know!
Please enable JavaScript in your browser to complete this form.

Or call us now

(+91)-7838002712

Contact us on the given number to buy any of our products.